« Back
Acid proof resistance sensor

Acid proof resistance sensor for hygienic applications

W-E-x-HST (datasheet 13), W-E-x-HST-...-HD (datasheet 13-HD)

Features

  • temperature sensor for hygienic installations
  • all parts made of acid proof steel
  • temperature range -200...+550 °C
  • Pt100 accuracy class A as a standard, more accurate on request
  • mounting by welding or with clamp connection
  • thermowell material according to the application
  • replaceable inner element, MI-construction, vibration proof
  • tailored solutions according to specific needs
  • ATEX Ex-i versions available
  • HD-versions for food product zone available.

Typical Applications

  • Food industry
  • Pharmaceutical industry
  • Chemical industry
  • Process industry
  • Energy and power plant technology
  • Machinery, plant and vessel construction.

Drawing 1 - version ...CLAMP...

Dimensions 1, data sheet 13
Dimensions of version ...CLAMP... with clamp flange thermowell

Drawing 2 - version ...S...

Dimensions 2, data sheet 13
Dimensions of version ...S... with welded ball thermowell
EHEDG-certificate logo

HD versions - W-E-x-HST-CLAMP/51-30/1000-4-A-yy-HD - are EHEDG Certified (TYPE EL Class I) for food product zone. Detailed information on the special datasheet 13-HD and on the installation and cleaning instruction sheet Instructions-13-HD, please see Downloads.


Features

  • HD = hygienic design, EHEDG certified
  • temperature sensor for hygienic installations
  • all parts made of acid proof steel
  • temperature range -200...+550 °C
  • Pt100 accuracy class A as a standard, more accurate on request.
  • mounting with clamp connection
  • thermowell material according to the application
  • replaceable sensing element, MI-construction, vibration proof
  • tailored solutions according to specific needs.


Typical Applications

  • Food industry
  • Pharmaceutical industry
  • Chemical industry
  • Process industry
  • Energy and power plant technology
  • Machinery, plant and vessel construction.

The EHEDG certificate copy of the W-E-x-HST-CLAMP/51-30/1000-4-A-yy-HD sensors (ehedg.org) »

What is EHEDG? »

Technical data

Thermowell material

AISI 316L, max. temp. +550 °C, temporarily +600 °C
other materials on request

Tolerances Pt100 (EN-60751)

HD-versions:
- A, tolerance +/- 0,15 + 0,002 x t, operating temperature -100...+450 °C
other versions also:
- B, tolerance +/- 0,3 + 0,005 x t, operating temperature -196...+600 °C
- B 1/3 DIN, tolerance +/- 1/3 x (0,3 + 0,005 x t), operating temperature -196...+600 °C
- B 1/10 DIN, tolerance +/- 1/10 x (0,3 + 0,005 x t), operating temperature -196...+600 °C

Temperature range Pt100

-200...+550 °C

Approvals

all versions:
- GOST-R, METROLOGICAL PATTERN APPROVAL
HD-versions also:
- EHEDG Type EL Class I certified

Quality certificate

ISO 9001:2008 issued by DNV

IP-class

IP65, higher IP-class on request

Hygienic well + Pt100 sensing element - example code:

.


Code key, data sheet 13
Click to open the code key image for non-certified versions
Code key, datasheet 13-HD
Click to open the code key image for EHEDG certified HD-versions.

Connections

Pt100 wire colors
Pt100 wire colors

Installation example

Installation, data sheet 13
Installation example of the welded version S, non-certified.
Installation, data sheet 13-HD
Installation example of the HD-version, EHEDG certified.

News

Visit us on booth 440 in hall 3A at NürnbergMesse, Messezentrum.

Read more

Visit our booth 6d80 in Messukeskus Helsinki.

Read more

SKS Automaatio’s WLT 310 wireless transmitter has been granted a LoRaWAN certificate – the very first to be granted in Finland for equipment designed for industrial use.

Read more
News archive

Contact